Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Inorg Chem ; 63(8): 3648-3655, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38353046

RESUMO

We report the crystal growth and characterization of a rare-earth-containing material, Dy3.00(1)Pt2Sb4.48(2). This compound possesses a similar structure to the previously reported Y3Pt4Ge6, but it lacks two layers of Pt atoms. Crystallographic disorder was found in Dy3.00(1)Pt2Sb4.48(2). Additionally, the Dy-Dy framework was found to have both square net and triangular lattices. Dy3.00(1)Pt2Sb4.48(2)8 was determined to be antiferromagnetically ordered around ∼15 K while a competing antiferromagnetic sublattice also exists at lower temperature. Strong magnetic anisotropy was observed, and several metamagnetic transitions were seen in the hysteresis loops. Furthermore, the Curie-Weiss fitting revealed an unusually small effective moment of Dy, which is far below the expected value of Dy3+ (10.65 µB). This material might provide a new platform to study the relationship between crystallographic disorder and magnetism.

2.
BMC Urol ; 20(1): 69, 2020 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-32539828

RESUMO

BACKGROUND: Holmium laser lithotripsy is the most common technique for the management of ureteral stone. Studies founded that holmium laser firing can produce heat which will cause thermal injury towards ureter. The aim of our current study is to explore factors affecting thermal effect of holmium laser during ureteroscopic lithotripsy. METHODS: An in vitro experimental model is design to simulate the ureteroscopic lithotripsy procedure. Different laser power settings (10w (0.5JX20Hz, 1.0 JX10Hz), 20w (1.0 JX20Hz, 2.0 JX10Hz), 30w (1.5JX20Hz, 3.0 JX10Hz)) with various firing time (3 s, 5 s, 10s) and irrigation flow rates(10 ml/min, 15 ml/min, 20 ml/min and 30 ml/min) were employed in the experiment. The temperature around the laser tip was recorded by thermometer. RESULTS: The temperature in the "ureter" rises significantly with the increasing laser power, prolonging firing time and reducing irrigation flow. The highest regional temperature is 78.0 °C at the experimental set-up, and the lowest temperature is 23.5 °C. Higher frequency setting produces more heat at the same power. Laser power < =10w, irrigation flow> = 30 ml/min and "high-energy with low-frequency" can permit a safe working temperature. CONCLUSION: We clarify that the thermal effect of holmium laser is related with both laser working parameters and irrigation flow. The proper setting is the key factor to ensure the safety during ureteroscopic holmium laser lithotripsy.


Assuntos
Queimaduras/etiologia , Lasers de Estado Sólido/efeitos adversos , Litotripsia a Laser/métodos , Cálculos Ureterais/terapia , Ureteroscopia , Lasers de Estado Sólido/uso terapêutico , Modelos Teóricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...